Welcome to Knowledge Base!

KB at your finger tips

This is one stop global knowledge base where you can learn about all the products, solutions and support features.

Categories
All
Storage and Backups-Netapp
How to correct ACP partial connectivity and Single Path HA on a FAS22xx platform

Applies to

FAS2000 series

Description

This article describes the procedure that should be followed to correct Alternate Control Path (ACP) partial connectivity and Single Path HA on a FAS22xx platform.

The following output is displayed:

NetApp Release 8.1 7-Mode: Thu Mar 29 13:56:17 PDT 2012
System ID: 1789379212 (ncdra00016n1); partner ID: 1789383578 (ncdra00016n2)
System Serial Number: 600000139685 (ncdra00016n1)
System Rev: B1
System Storage Configuration: Single-Path HA
System ACP Connectivity: Partial Connectivity

Note: Without any external disk shelves, the FAS22XX series controller has only one path to the disks on the internal shelf, and there is no connection to the ACP lock-wrench port e0P.

Troubleshooting Workflow: cluster join failure

Applies to

Clustered Data ONTAP 8.2

Issue

Check Active IQ if this impacts your systems

Cluster join failure

Read article
How to troubleshoot MetroCluster check cluster errors

Applies to

  • MetroCluster
  • metrocluster check
  • Cluster errors

Description

MetroCluster check reports errors on the cluster object:

ClusterA::> metrocluster check show

Last Checked On: mm/dd/yyyy hh:mm:ss

Component           Result
------------------- ---------
nodes               ok
lifs                ok
config-replication  ok
aggregates          ok
clusters            warning
5 entries were displayed.

Read article
What is the recommended Fillword setting for using 8GBps Brocade switches?

Applies to

  • Brocade 8GBps Switches
  • Brocade 300
  • Brocade 5100

Question(s) and Answer(s)

What are Fillwords in a fibre channel environment and what does NetApp recommend they be set at?

What is the recommended Fillword setting for using 8GBps Brocade switches?

Fillwords are 4-byte words without a special task. A port sends them when it does not have to send something else. They are used to maintain the synchronization of the link.

The recommended Fillword setting is 3.

E ports and ISL ports may require different settings depending on xWDM vendors. Contact the vendors in both of these situations.

The available Fillword values are as follows:

0 | -idle-idle Sets IDLE mode in the Link Init and IDLE as the fill word (default).
1 | -arbff-arbff Sets ARB(ff) in the Link Init and ARB(ff) as the fill word.
2 | -idlef-arbff Sets IDLE mode in the Link Init and ARB(ff) as the fill word.
3 | -aa-then-ia Attempts hardware arbff-arbff (mode 1) first. If the attempt fails to go into active state, this command executes software idle-arb (mode 2). Mode 3 is the preferable to modes 1 and 2 as it captures more cases.

The difference is that '3' attempts '1' and then '2'.

Note :

  • Changing fillword is a disruptive event as the port will bounce when this change is made.
  • Some third-party storage vendors might require different Fillwords for their storage than
  • E ports and ISL ports may require different settings depending on xWDM vendors. Contact the vendors in both of these situations.
Read article
How to identify a device by its World Wide Name (WWN) or MAC address?

Applies to

ONTAP

Description

The Organizationally Unique Identifier (OUI) is built into all MAC addresses and World Wide Node and Port names. The naming format used will determine which part of the name is the OUI.

Read article
LUNs or NFS mount not accessible after DR Operation (CFOD)

Applies to

  • MetroCluster
  • ONTAP 8.2
  • Volume has nvfail setting turned on

Issue

After a CFOD (Cluster Failover on Disaster) event:

  • Servers lose connectivity to NFS mounts and need to be remounted.
  • LUNs are offline

node1> vol options vol1
nosnap=off, nosnapdir=off, minra=off, no_atime_update=off, nvfail=on ,
ignore_inconsistent=off, snapmirrored=off, create_ucode=off,

Read article