Storage and Backups-Netapp
How to enter the filer's CIFS shares in the DFS root tree
Applies to
Description
Distributed File System for Microsoft Windows NT Server (DFS) allows distributed file systems capabilities on Windows NT Server. A distributed file system provides a single tree structure for multiple shared volumes located on different servers. A user accessing a share using DFS doesn't need to know the name of the server where the share resides.
If a file server goes down, or if you need to move a volume from one server to another, you can do so without informing users of the change. You can increase data availability and transparently distribute load across multiple servers by using duplicate storage points for a single volume.
SyncMirror could not create resynchronization snapshot (1045120)
Applies to
-
SyncMirror
-
FlashPool
-
MetroCluster
-
ONTAP 9.1 and earlier
-
SYNCMIRROR SNAPSHOTS NOT ROTATING autosupport message
Issue
There is no space left on aggregate with Flashpool (Hybrid Aggregates) configured.
Fri FebFri Feb 7 09:10:11 CET [systemname:raid.mirror.resync.snapcrtfail:warning]: Aggregate <aggr_name>: could not create mirror resynchronization snapshot mirror_resync. (No space left on device)
SyncMirror could not create resynchronization snapshot (SSD space)
Applies to
-
SyncMirror
-
FlashPool
-
MetroCluster
-
ONTAP 9.2 and later
-
SSD space lower than 1%
Issue
There is no space left on aggregate with Flashpool configured
Fri FebFri Feb 7 09:10:11 CET [systemname:raid.mirror.resync.snapcrtfail:warning]: Aggregate <aggr_name>: could not create mirror resynchronization snapshot mirror_resync. (No space left on device)
MetroCluster cluster name mismatch after changing cluster name
Applies to
-
ONTAP 9
-
MetroCluster
-
Cluster renamed
Issue
"metrocluster show" reports different peer cluster names
Cluster A Local: ClusterA Remote: cluster_oldB
Cluster B Local: ClusterB Remote: cluster_oldA
ClusterA::> metrocluster show
Configuration: fabric
Cluster Entry Name State
------------------------------ ---------------------- ---------------------
Local: ClusterA
Configuration State configured
Mode normal
AUSO Failure Domain auso-on-cluster-disaster
Remote: cluster_oldB
Configuration State configured
Mode normal
AUSO Failure Domain auso-on-cluster-disaster
ClusterA::> cluster peer show
Peer Cluster Name Cluster Serial Number Availability Authentication
------------------------- --------------------- -------------- --------------
ClusterB 1-80-000011 Available ok
Can a Volume ID be reused in Element Software?
Applies to
Element Software.
Answer
No. The Volume ID is uniquely generated for every volume that is created. Even if a volume is deleted, the number will always increment when a new volume is created based on the last Volume ID that was used.
Data ONTAP 8: How to accurately determine CPU utilization of a Data ONTAP 8.0 Cluster-Mode cluster
Applies to
-
Clustered Data ONTAP 8
-
PERF
Description
How to use the various statistics commands to determine which controller and CPU is running hot in a Data ONTAP 8.0 Cluster-Mode cluster?