Welcome to Knowledge Base!

KB at your finger tips

This is one stop global knowledge base where you can learn about all the products, solutions and support features.

Categories
All
Storage and Backups-Netapp
How to troubleshoot MetroCluster check config replication errors

Applies to

  • MetroCluster
  • metrocluster check
  • Config replication errors

Description

MetroCluster check reports errors on the node object:

ClusterA::> metrocluster check show

Last Checked On: mm/dd/yyyy hh:mm:ss

Component           Result
------------------- ---------
nodes               ok
lifs                ok
config-replication  warning
aggregates          ok
clusters            ok
5 entries were displayed.

FAS8020 storage initiator connection rules in a MetroCluster solution

Applies to

  • MetroCluster
  • ONTAP 9
  • FAS8020 only

Issue

In a MetroCluster in clustered Data ONTAP, each controller must have two HBA initiator connections to each of the two fabrics to connect storage. Along with that, each controller requires four HBA initiator ports.

When using FAS8020 controllers, there might be a need to only use two, instead of four, HBA initiator ports to connect storage to use the single free slot for host connectivity or tape backup. This applies to the FAS8020 only and no other platform. This type configuration can also be called as a 'single initiator per fabric' configuration.

Note : If a MetroCluster is configured using FAS8020 controllers and the hardware configuration is changed, these rules must be evaluated in order to add / remote paths so the configuration remains supported.

Read article
FC-SAS Bridge Health Monitoring collection is older than 24 hours

Applies to

  • ATTO FibreBridge
  • MetroCluster
  • ONTAP 9
  • Out of band management

Description

FC-SAS Bridge Health Monitoring collection is older than 24 hours. The data collection for the FC-SAS Bridge is not current, and this will impact the ability to troubleshoot issues and indicate configuration issues.

Read article
Are FAS3240/V3240 and FAS3270/V3270 supported in MetroCluster running DATA Ontap 8.3 or later?

Applies to

  • FAS3240/V3240
  • FAS3270/V3270
  • ONTAP 8.3
  • ONTAP 9

Answer

FAS3240/V3240 and FAS3270/V3270 are not supported in MetroCluster running Data ONTAP 8.3 or later.

See the Interoperability Matrix for a list of supported configurations.

Additional Information

Read article
How to configure the Data ONTAP subnet feature in a MetroCluster

Applies to

  • MetroCluster
  • ONTAP 9
  • subnet feature

Description

This article describes the procedure to configure the Data ONTAP subnet feature in a MetroCluster.

Read article
How to identify a mismatch of shortwave and longrange SFPs in a FC-VI card?

Applies to

  • MetroCluster FC
  • FCVI
  • long wave and short wave intermix

Description

SFPs need to be the same for both ports on the FCVI card. The below procedure explains how to identify a mismatch.
In order to decide on the correct type of SFP you need to verify the infrastructure (cables / patch pannels) used in the datacenter.

Read article